Home Company Profile Technical Support Software Updates Contact App-Tek Global Network
 

The OdaLog has been specifically designed for the Wastewater Industry, primarily for locating at or close to the source of Hydrogen Sulphide emissions such as within sewerage pumping stations and receiving manholes.

Its purpose is to log levels of H2S in the range 0-200 ppm for later downloading of data in tabular or graphical form to highlight significant variations in H2S levels over time.

Due to the nature of the environment in which the instrument has to operate, it has been designed to be splash resistant, robust, small, and able to log data for extended periods of time.

The following is detailed information on this globally recognised product.

 

  • Displays Line Graphs
  • Ability to zoom in on selected time periods
  • Ability to export data to spreadsheets
  • Ability to customise graphical scale and mark time intervals on X-axis
  • Records OdaLog serial number on printout and allows graphs to be labelled
  • Uses Infra Red Communication for downloading and configuring
  • 32,000 logging intervals allow very detailed or very long studies e.g.
    • Over 3 months at 5 minute intervals
    • Over 3 weeks at 1 minute intervals
    • Over 3 days at 10 second intervals

 


 SENSOR TYPE:

Electrochemical Hydrogen Sulphide (other gases available)

 MAX RANGE:

0 to 999.9 ppm

 STD RANGE:

0 to 200.0 ppm

 ACCURACY AT STP:

+/- 2.0 ppm

 RESOLUTION:

0.1 ppm

 RESPONSE TIME:

T90 < 60 seconds

 PRESSURE RANGE:

Atmospheric +/- 10%

 RELATIVE HUMIDITY RANGE:

15 to 90% (non-condensing)

 INSTRUMENT TEMP RANGE:

-10 C to 40 C

 EXTERNAL DIMENSIONS:

165mm x 62mm Dia

 INSTRUMENT WEIGHT:

450 grams

   
 INSTRUMENT POWER SUPPLY  
 POWER SUPPLIES: 3 x 1.5V, Approved AA Alkaline Batteries or Optional 1 x 3.6V, Approved C Lithium Battery, Factory Fitted
 BATTERY LIFE: Alkaline Over 3 Months
Lithium Over 6 Months
   
 DATA LOGGER  
 MEMORY CAPACITY: 32,000 Readings
 LOGGING INTERVAL: Selectable from 1 second to 1 hour (e.g.) 1 min interval logs for 22 days, 5 min interval logs over 3 Mths
 


INTRINSIC SAFETY
Standards Australia Certificate AUS Ex 2478X, certified to EX ia I/IIC T4 (Tamb = -20 Deg C to +50 Deg C)
IP66/67.

NEMKO Nemko 03ATEX134, certified to I M2 / II 2 GD, EEx ia I/IIC T4 IP66/67

ELECTROMAGNETIC COMPATIBILITY
The OdaLog Type I and accessories have been tested and conform to the requirements of C-Tick, CE & FCC.

CERTIFICATION CONDITIONS OF SAFE USE
It is a condition of safe use that the App-Tek Model OdaLog® Type I Logger:

1. The instruction manuals shall be read and understood prior to use of this instrument.
2. For group I applications, the instrument shall be used in the leather case.
3. The certification does not cover the instrument for use in oxygen enriched atmospheres.
4. The alkaline and lithium batteries shall only be removed or replaced in a non-hazardous area.
5. Batteries must be replaced with one of the following types listed in Table 1.

Table 1 : Approved Battery Types

 Manufacturers Part Number Code Type Size
 Duracell MN 1500 Alkaline AA
 Procell PC1500 Alkaline AA
 Energiser E91 Alkaline AA
 Energiser EN91 Alkaline AA
 Saft LS26500 Lithium C
 Tadiran TL-5920/S Lithium C

 


We recommend that the OdaLog is returned to an authorised App-Tek service centre at least once every six months for a full inspection, software upgrade as developed, calibration, test for linearity and to have new batteries fitted.



12 month warranty when used in accordance with the operator's manual (excluding calibration costs).

In the interest of continued improvement, we reserve the right to change design features without prior notice.